Batch Register

Pricing and rates feed

None of the published texts sets a fixed period on this consumer; every row below reads no period set by the text. Paste one job that feeds this consumer, for example fx_rates_feed, weekly, and the register reads its period against the clocks below, names the gap in hours, and carries the question for its owner.

Matched on the job name or the consumer column by these words: rates feed, price feed, fx rates, pricing feed, pricing, rate update, rates feed. A backup, replication, feed or return job in this class is expected to name a fallback; a blank one is a finding.

The clock each rule sets

RegimeClockClause
DORAno clockDORA Art. 11 Response and recovery
ISO/IEC 25012:2008 named referenceno clockISO/IEC 25012 Currentness Currentnessquoted below

Named reference beside this class, ISO/IEC 25012 Currentness Currentness: The degree to which data have attributes that are of the right age in a specific context of use; the acceptable age depends on the use, from real time to historical. A data quality requirement, measure or evaluation using the model is categorised under this characteristic (inherent point of view).

Questions this page answers

How often does DORA (Regulation (EU) 2022/2554) require pricing and rates feed?

The text of DORA Art. 11 (Response and recovery) sets no fixed period: no period set by the text. Financial entities adopt an ICT business continuity policy within their overall continuity policy and implement it through documented arrangements that keep critical or important functions running, contain and resolve incidents, estimate preliminary impacts, and drive crisis communication and reporting under Articles 14 and 19; they run a business impact analysis, keep ICT response and recovery plans, test, at least once a year and after substantive changes, the continuity and response plans for the systems behind every function, test crisis communication plans, and keep records of activity during disruptions. Entities other than microenterprises additionally have the response and recovery plans reviewed by independent internal audit (Art. 11(3)), include cyber-attack and switchover scenarios in testing (Art. 11(6)), run a crisis management function (Art. 11(7)), and estimate aggregated annual costs and losses of major incidents when the authority asks (Art. 11(10)). Central securities depositories also send continuity test results to the authority (Art. 11(9)). Entities listed in Article 16(1) are outside this Article and follow the simplified framework of Article 16 instead.

What does the register ask the owner of a pricing and rates feed job?

How old may a rate be before it is stale for the use it serves, and does the period match?

The clauses in full

DORA Art. 11 Response and recoverythe standard's page

Financial entities adopt an ICT business continuity policy within their overall continuity policy and implement it through documented arrangements that keep critical or important functions running, contain and resolve incidents, estimate preliminary impacts, and drive crisis communication and reporting under Articles 14 and 19; they run a business impact analysis, keep ICT response and recovery plans, test, at least once a year and after substantive changes, the continuity and response plans for the systems behind every function, test crisis communication plans, and keep records of activity during disruptions. Entities other than microenterprises additionally have the response and recovery plans reviewed by independent internal audit (Art. 11(3)), include cyber-attack and switchover scenarios in testing (Art. 11(6)), run a crisis management function (Art. 11(7)), and estimate aggregated annual costs and losses of major incidents when the authority asks (Art. 11(10)). Central securities depositories also send continuity test results to the authority (Art. 11(9)). Entities listed in Article 16(1) are outside this Article and follow the simplified framework of Article 16 instead.

What an assessor asks to see: ICT business continuity policy and the business impact analysis it rests on; ICT response and recovery plans with yearly test reports and tests after substantive changes; Crisis communication plan test record and records kept during actual disruptions; Internal audit review of the response and recovery plans, crisis management function terms of reference and cyber-attack and switchover test scenarios (entities other than microenterprises). Where it usually falls short: Plans tested only for critical systems, not for systems supporting all functions

ISO/IEC 25012 Currentness Currentnessnamed referencethe standard's page

The degree to which data have attributes that are of the right age in a specific context of use; the acceptable age depends on the use, from real time to historical. A data quality requirement, measure or evaluation using the model is categorised under this characteristic (inherent point of view).

What an assessor asks to see: Timestamps and refresh cadence per data set against the use's tolerance. Where it usually falls short: Reference data refreshed yearly for a daily decision

Requirement text is our own statement of each clause, from the standards published at compliance.theartofservice.com, the same publisher as this register, read against the published text of each standard: our statement of each clause, not the instrument verbatim. Run this job through the register